Battery return series is a new type of electric actuators with the function of battery returning when
power failure occurred. It can be preset to “Fully open”, “Fully close”, “No action” or “Stagnation position”and return to a safe position to protect devices or equipment’s safety when power failure occurred.
IN GENERAL
The actuator, specifically designed for 90° operation(e.g., ball valves,butterfly valves). The failsafe function by means of a Supercap Capacitator ensures OPEN or CLOSED position on power loss.The supercap is charged via the actuator power supply in operational mode.
FAIL-SAFE
The failsafe is purely an emergency function and serves no other purpose.
Actuator is operated electricallyin normaluse
CHARGING
The condenser are charging automatically during the normal operation.