The electric actuator runs under load, and the planetary gear ring connected to the motor transmits the torque. Once the load exceeds the allowable maximum value, the transmission member installed on the outer edge of the internal gear and equipped with two helical cylindrical springs that balance the forward and reverse torques will be toggled, so that the torque spring member moves left and right. When the torque is exceeded, the transmission part drives the connecting rod to trigger the action of the torque micro-switch in this direction to generate an instantaneous electrical signal. If the over-torque of the actuator only alarms once, it needs to be assisted by the special relay in the circuit board, so that the electric actuator will stop running.